Bridge window clarity
10-minute backup gives teams a defined window for generator start, transfer, and safe operational response.
Data center UPS bridge power
A compact high-rate LFP battery rack for data center transfer windows, generator synchronization, and controlled shutdown. Designed around 512V architecture, 10-minute 6C discharge, and a single-rack footprint for AI, colocation, edge, and enterprise UPS rooms.

The page has been rebuilt around the information a data center facilities, electrical, or procurement team needs first: output, runtime, voltage, footprint, compatibility, risk controls, and next-step engineering review.
10-minute backup gives teams a defined window for generator start, transfer, and safe operational response.
6C discharge supports UPS bridging applications where short-duration power density matters more than long-duration storage.
A single 600 x 1000 x 2000 mm rack reduces room planning complexity compared with distributed battery strings.
Positioned for common UPS environments including Vertiv, Eaton, Delta, APC, and project-specific integration review.
The two rack configurations keep the same 512V UPS voltage and 10-minute discharge profile, with different capacity and output options for 250K/300K backup planning.
| Parameter | Model 235K (85Ah) | Model 250K (100Ah) |
|---|---|---|
| Power output | 235 kW | 250 kW |
| Backup time / rate | 10 min / 6C | 10 min / 6C |
| System voltage | 512 V | 512 V |
| System capacity | 85 Ah | 100 Ah |
| Battery module | 51.2V85 | 51.2V100 |
| System energy | 43.5 kWh | 51.2 kWh |
| Rack dimensions | 600 x 1000 x 2000 mm | |
| UPS compatibility | Project review for Vertiv, Eaton, Delta, APC, and other UPS platforms | |

For US data center teams, the strongest message is operational confidence. The rack should help facilities teams answer whether the battery can bridge the transfer window, fit the room, communicate with the UPS, and simplify maintenance planning.
The redesigned page presents the rack as a mission-critical component, not a generic battery product.
Short-duration, high-power UPS support for dense compute loads where transfer timing is critical.
Rack-level backup planning for facilities balancing footprint, uptime commitments, and serviceability.
Compact backup for distributed rooms that need predictable runtime without a large battery footprint.
It means the rack is positioned for short-duration bridge power, typically covering transfer, generator start, or controlled shutdown timing.
No. It is a high-rate UPS battery rack. Final system behavior depends on the UPS, protection design, controls, and site integration.
LFP chemistry supports compact, high-rate backup with strong thermal stability compared with legacy battery approaches.
Send your UPS brand, required load, runtime target, room constraints, and project location. FNS Power can help confirm the right rack configuration for your data center backup design.