Sodium-ion UPS battery for critical power

522V 100Ah Sodium-Ion UPS Battery for Data Centers

A high-voltage sodium-ion battery cabinet for data center UPS backup, engineered around wide-temperature operation, fast discharge response, and safer chemistry for critical infrastructure projects.

522V 100Ah sodium-ion battery cabinet for data center UPS backup
522V 100Ah sodium-ion battery cabinet for high-voltage UPS backup in data center environments.

522V DCNominal UPS voltage
100AhRated capacity
-40°C to +60°CWide operating range
3C / 5C peakHigh-rate discharge
4,500+ cyclesDesign cycle life

Designed for the questions data center teams ask first

The redesigned page brings the decision-making details into the first screen: voltage, capacity, temperature range, discharge profile, safety rationale, and the next engineering step.

Cold-site resilience

Sodium-ion chemistry supports operation in low-temperature environments where conventional battery systems may require extra heating strategy.

UPS response

High-rate discharge positioning helps bridge transfer windows, generator start, and controlled shutdown requirements.

Thermal stability

The chemistry is presented around safety, stability, and infrastructure-grade reliability rather than consumer battery language.

Project review ready

Clear specs and compatibility notes help facilities, electrical, and procurement teams start a technical review faster.

Technical specifications

Use these values as a starting point for UPS DC bus, runtime, battery monitoring, and protection review.

Parameter Specification Planning note
Nominal voltage 522V DC High-voltage UPS battery architecture
Rated capacity 100Ah (C3) Sized for project-specific runtime review
Chemistry Sodium-ion Reduced lithium dependency and strong thermal stability
Operating temperature -40°C to +60°C Useful for cold rooms, outdoor-adjacent rooms, and harsh sites
Discharge rate 3C continuous / 5C peak Supports high-rate UPS transfer and short-duration backup
Cycle life ≥ 4,500 cycles At 25°C and 80% DOD reference conditions
Final selection should be validated against UPS DC bus requirements, BMS communication, breaker/protection design, thermal limits, room layout, seismic needs, and local code requirements.

UPS battery room benchmark for sodium-ion backup design

Use real UPS rooms as the benchmark

For US data center buyers, the strongest first impression is not a decorative graphic. It is a product and a set of operating data that can be discussed with facilities, electrical, safety, and procurement teams.

Application fit

The page now positions sodium-ion as a critical-power option for specific deployment constraints, not as a generic battery novelty.

Data center UPS

High-voltage backup for facilities evaluating safer chemistry and high-rate discharge.

Edge and telecom rooms

Useful for distributed sites where temperature range and maintenance simplicity matter.

Cold-climate infrastructure

Suitable for projects where low-temperature performance is part of the design conversation.

FAQ

What makes this battery different?

It uses sodium-ion chemistry for high-voltage UPS backup, emphasizing wide-temperature operation and high-rate discharge.

Is this a complete UPS system?

No. It is a battery cabinet/module solution. Final system behavior depends on UPS integration, controls, protection, and site engineering.

Who should review the specification?

Facilities, electrical engineering, procurement, safety, and UPS integration teams should validate the final configuration together.

Related data center power pages

Plan a 522V sodium-ion UPS battery review

Send the UPS brand, DC bus requirements, target runtime, ambient temperature range, monitoring requirements, and project location. FNS Power can help review whether sodium-ion fits the backup design.